MOUNTING ACCESSORIES Exhaust and/or supply valves: Accessories RDR Air volume regulators, fi tted inside a duct to maintain constant air volume within a pressure range from 50 to 200 Pa. • The airfl ow can be adjusted during installation. • The regulators can be used in commercial premises, both in ventilation and air treatment (max 60ºC) as well as in air extraction or impulsion. • It can be used in dwellings with double-fl ow installation. • Easy to fi t inside the duct. • Sealing and stability provided by a foam joint. • Manufactured from fl ame retardant plastic (M1 fi re classifi cation), with limit of operation at 60ºC. Ø 80 mm Ø 100 mm Ø 125 mm Model Airfl ow Airfl ow regulation options Model Airfl ow Airfl ow regulation options Model Airfl ow Airfl ow regulation options (m/h) (m/h) in sections of (m/h) (m/h) (m/h) in sections of (m/h) (m/h) (m/h) in sections of (m/h) 3 3 3 3 3 3 3 3 3 RDR-80/15 15 15 to 50 2,5 RDR-100/30 30 15 to 50 5 RDR-125/30 30 15 to 50 5 RDR-80/30 30 15 to 50 2,5 RDR-100/45 45 15 to 50 5 RDR-125/45 45 15 to 50 5 RDR-80/45 45 15 to 50 2,5 RDR-100/50 50 15 to 50 5 RDR-125/60 60 50 to 100 5 Data of Ø (mm) and airflow (m3/h) are included RDR-100/60 60 50 to 100 5 RDR-125/75 75 50 to 100 5 in the reference of RDR models. RDR-100/75 75 50 to 100 5 RDR-125/90 90 50 to 100 5 RDR- Ø / airflow RDR-100/90 90 50 to 100 5 RDR-125/120 120 100 to 180 5 RDR-125/150 150 100 to 180 5 RDR-125/180 180 100 to 180 5 Ø 160 mm Ø 200 mm Ø 250 mm Model Airfl ow Airfl ow regulation options Model Airfl ow Airfl ow regulation options Model Airfl ow Airfl ow regulation options (m/h) (m/h) in sections of (m/h) (m/h) (m/h) in sections of (m/h) (m/h) (m/h) in sections of (m/h) 3 3 3 3 3 3 3 3 3 RDR-160/150 150 100 to 180 5 RDR-200/240 240 180 to 300 10 RDR-250/350 350 300 to 500 25 RDR-160/180 180 100 to 180 5 RDR-200/270 270 180 to 300 10 RDR-250/400 400 300 to 500 25 RDR-160/210 210 180 to 300 5 RDR-200/300 300 180 to 300 10 RDR-250/450 450 300 to 500 25 RDR-160/240 240 180 to 300 5 RDR-200/350 350 300 to 500 10 RDR-250/500 500 300 to 500 25 RDR-160/270 270 180 to 300 5 RDR-200/400 400 300 to 500 10 RDR-250/550 550 500 to 750 25 RDR-160/300 300 180 to 300 5 RDR-200/450 450 300 to 500 10 RDR-250/600 600 500 to 750 25 RDR-200/500 500 300 to 500 10 RDR-250/650 650 500 to 750 25 RDR-250/700 700 500 to 750 25 Regulators Regulators RD Ø 80 et 100 mm Regulators RD Ø 125 à 250 mm Before carrying out the implementation of the regulator, it is necessary to calibrate the airfl ow: 1. Loosen the screws of the adjustment module. 2. Adjust the marker module (located on the left or right) in front of the desired airflow rate. 3. Tighten the screws of the adjustment module. It is possible to get other rates that those indicated on the controller by shimming the mark on the control module on a intermediary position. Example of regulator at 50 m3/h Example of regulator at 180 m3/h Composition and design RDR D1 (mm) D2 (mm) L (mm) D2 Ø 80 76 76 55 1 2 Ø 100 96 93 70 Ø 125 120 117 86 Ø 150 146 148 91 3 Ø 160 146 148 91 4 Ø 200 190 195 91 Ø 250 245 236 127 5 6 D1 1 ExtBrush seal 2 Spacer (as output) L 3 Casing 4 Flap 5 Airfl ow control module 6 Locking screw adjustment mode 38 Mounting accessories www.solerpalau.com