MOUNTING ACCESSORIES Air vents (Air inlets) REGULATIONS • Air must be able to circulate from the dry to the damp rooms, • The air vents must be placed more than 1.80 m above fl oor therefore, the dining rooms, bedrooms and living rooms must level. have inlet openings. MOUNTING ALTERNATIVES IN THE ROLLER BLIND BOX IN THE WINDOW FRAME IN WALL WITH SOUND ATTENUATOR Air vent Facade Air vent Air vent cap Facade grille WITHOUT SOUND ATTENUATOR FIXING POINTS AND AIRFLOW 372 354 160 60 R R Air vent 10 R: Groove Two grooves (R) of 160x12mm should be done, with 10mm separation between them. Facade cap Fixing points Afterwards, the inlet should be fi xed in the 3 fi xing points. AIR VENTS MODELS Self-regulating air vents: Humidity adjustable air vents: The airfl ow circulating through the vent is maintained constant. The airfl ow circulating through the vent depends on the relative An inner fl exible element avoids sudden increases of airfl ow humidity of the indoor air. When it is high, a fl ap located inside caused by wind blowing onto the facade of the building. the vent keeps the air passage totally open (maximum fl ow), while when the relative humidity indoors is low, the fl ap closes (minimum airfl ow), reducing energy loss. Operation (at 20Pa) 50 4 0 0 0 20 30 40 50 60 70 80 Relative Humidity RH% 22 Mounting accessories www.solerpalau.com irlf o in 3/h 1 OInustsididee OOuuIInnttssssiiiiddddeeeeOuIntssiiddee m30w20A1