LAUFEN INSTALLATION SYSTEM TW2 Concealed cistern for floorstanding WC pan 89466.4 TECHNICAL DATA Order no. 89466.4 Mounting acc. incl. Fastening set for the wall, WC connection set, Certified to EN 14055 flush pipe connector) matching for All LAUFEN floorstanding WC pans and angle valve 1/2”. Specifications For mounting in front of a solid or drywall Accessories excl. Actuator plates dual flush, order no. 89566.1, construction, concealed installation,with frontal 89566.2 (stainless steel) actuator, with water condensation insulation. Electronic actuator plate dual flush, Dual-Flush 6/3-l (4,5/3-l-flush). order no. 89566.3,89566.4 Flush valve with silicon seal. Mounting information Please note the necessary wall thickness of 80 mm Fill valve with anti-siphon system. in case of pre-wall installation. Height from Water inlet top or rear R 1/2”, brass finished floor to top of WC pre-set to 400 mm, Flow pressure range 0.5-10 bar adjustable between 390-450 mm. Water temperature max. 25°C Height dimension from finished floor to feeding Tank Thickness 110 mm, material PP elbow of the toilet flange. Installation depth 125 mm System installation is also possible between Weight 3,8 kg modular walls (plasterboard). Colours White TECHNICAL DRAWINGS / S 1 : 20 530 500 12525-75 50 63 R /“ 50 R /“ R /“ Z 170405 51451752 546